N2 - We demonstrate the feasibility of using the dominant frequency of the sample surface response to a mechanical stimulation as an effective indicator for sensing the depth wise distribution of elastic properties in transparent layered phantom samples simulating the cortex and nucleus of the crystalline lens. Focused ultrasound waves are used to non invasively interrogate the sample surface. A phase-sensitive optical coherence tomography system is utilized to capture the surface dynamics over time with nanometer scale sensitivity. Spectral analysis is performed on the sample surface response to ultrasound stimulation and the dominant frequency is calculated under particular loading parameters. Pilot experiments were conducted on homogeneous and layered tissue-mimicking phantoms. Results indicate that the mechanical layers located at different depths introduce different frequencies to the sample surface response, which are correlated with the depth-dependent elasticity of the sample. The duration and the frequency of the ultrasound excitation are also investigated for their influences on this spectrum-based detection. This noninvasive method may be potentially applied for localized and rapid assessment of the depth dependence of the mechanical properties of the crystalline lens.
AB - We demonstrate the feasibility of using the dominant frequency of the sample surface response to a mechanical stimulation as an effective indicator for sensing the depth wise distribution of elastic properties in transparent layered phantom samples simulating the cortex and nucleus of the crystalline lens. Focused ultrasound waves are used to non invasively interrogate the sample surface. A phase-sensitive optical coherence tomography system is utilized to capture the surface dynamics over time with nanometer scale sensitivity. Spectral analysis is performed on the sample surface response to ultrasound stimulation and the dominant frequency is calculated under particular loading parameters. Pilot experiments were conducted on homogeneous and layered tissue-mimicking phantoms. Results indicate that the mechanical layers located at different depths introduce different frequencies to the sample surface response, which are correlated with the depth-dependent elasticity of the sample. The duration and the frequency of the ultrasound excitation are also investigated for their influences on this spectrum-based detection. This noninvasive method may be potentially applied for localized and rapid assessment of the depth dependence of the mechanical properties of the crystalline lens.
UR - http://www.scopus.com/inward/record.url?scp=84888783131&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84888783131&partnerID=8YFLogxK
U2 - 10.1364/BOE.4.002769
DO - 10.1364/BOE.4.002769
M3 - Article
AN - SCOPUS:84888783131
VL - 4
SP - 2769
EP - 2780
JO - Biomedical Optics Express
JF - Biomedical Optics Express
IS - 12
ER -