TY - JOUR
T1 - Cross-correlation vibro-acoustic modulation method for damage detection
AU - Liu, Dong
AU - Donskoy, Dimitri
N1 - Publisher Copyright:
© The Author(s) 2023.
PY - 2024/3
Y1 - 2024/3
N2 - The vibroacoustic modulation (VAM) method distinguishes itself from other linear or nonlinear acoustic structure health monitoring methods due to its advantages of high sensitivity, relatively simple implementation, and the capability to detect defects in complex structures. However, the damaged index of VAM—modulation index, which is used for quantifying the damage severity, is highly influenced by the frequency of the probe wave. To increase the reliability and robustness of the VAM method, researchers modified it by replacing the single harmonic probe wave with a chirp signal. The instantaneous frequency of the chirp signal linearly increases with time, allowing the modified VAM method to access the broadband frequency range in a relatively short amount of time. However, the sideband that attributes to the acoustic nonlinearity of the defect would be overwhelmed by the broadband frequency content of the probe wave. Hence, a different algorithm is needed to process the received signal of the modified VAM method. Previous studies have employed short-time Fourier transform, wavelet transform, Hilbert transform, and synchronous demodulation for this purpose. Yet, these signal processing methods do not take into account affection of the phase difference between the probe and pump waves to the final result. To address this issue, this paper proposes using a cross-correlation (CC) approach. The performance of the proposed CC approach and existing methods were compared using simulation and experimental testing, evaluating their ability to detect acoustic nonlinearity.
AB - The vibroacoustic modulation (VAM) method distinguishes itself from other linear or nonlinear acoustic structure health monitoring methods due to its advantages of high sensitivity, relatively simple implementation, and the capability to detect defects in complex structures. However, the damaged index of VAM—modulation index, which is used for quantifying the damage severity, is highly influenced by the frequency of the probe wave. To increase the reliability and robustness of the VAM method, researchers modified it by replacing the single harmonic probe wave with a chirp signal. The instantaneous frequency of the chirp signal linearly increases with time, allowing the modified VAM method to access the broadband frequency range in a relatively short amount of time. However, the sideband that attributes to the acoustic nonlinearity of the defect would be overwhelmed by the broadband frequency content of the probe wave. Hence, a different algorithm is needed to process the received signal of the modified VAM method. Previous studies have employed short-time Fourier transform, wavelet transform, Hilbert transform, and synchronous demodulation for this purpose. Yet, these signal processing methods do not take into account affection of the phase difference between the probe and pump waves to the final result. To address this issue, this paper proposes using a cross-correlation (CC) approach. The performance of the proposed CC approach and existing methods were compared using simulation and experimental testing, evaluating their ability to detect acoustic nonlinearity.
KW - Vibroacoustic modulation
KW - cross correlation
KW - nondestructive testing
KW - nonlinear acoustic
KW - signal processing method
KW - structural health monitoring
UR - http://www.scopus.com/inward/record.url?scp=85162977668&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85162977668&partnerID=8YFLogxK
U2 - 10.1177/14759217231177005
DO - 10.1177/14759217231177005
M3 - Article
AN - SCOPUS:85162977668
SN - 1475-9217
VL - 23
SP - 836
EP - 855
JO - Structural Health Monitoring
JF - Structural Health Monitoring
IS - 2