T1 - Feasibility of distributed fiber optic sensor for corrosion monitoring of steel bars in reinforced concrete
AU - Fan, Liang
AU - Bao, Yi
AU - Chen, Genda
N1 - Publisher Copyright:
© 2018 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2018/11
Y1 - 2018/11
N2 - This study investigates the feasibility of distributed fiber optic sensor for corrosion monitoring of steel bars embedded in concrete. Two sensor installation methods are compared: (1) attaching the sensor along the bar and (2) winding the sensor on the bar. For the second method, optical fibers were winded spirally on steel bars with different spacings: 0 mm, 2 mm, 5 mm, and 10 mm. Steel bar pull-out testing was conducted to evaluate the effect of presence of distributed sensor on the bond strength of steel–concrete interface. Electrochemical testing was carried out to assess the influence of the installation methods on the corrosion resistance of the reinforced concrete. Winding the optical fiber on steel bars with a 10-mm spacing does not affect the bond strength and corrosion resistance and allows real-time corrosion monitoring. The distributed sensor data can be used to estimate the corrosion induced steel loss and predict concrete cracking.
AB - This study investigates the feasibility of distributed fiber optic sensor for corrosion monitoring of steel bars embedded in concrete. Two sensor installation methods are compared: (1) attaching the sensor along the bar and (2) winding the sensor on the bar. For the second method, optical fibers were winded spirally on steel bars with different spacings: 0 mm, 2 mm, 5 mm, and 10 mm. Steel bar pull-out testing was conducted to evaluate the effect of presence of distributed sensor on the bond strength of steel–concrete interface. Electrochemical testing was carried out to assess the influence of the installation methods on the corrosion resistance of the reinforced concrete. Winding the optical fiber on steel bars with a 10-mm spacing does not affect the bond strength and corrosion resistance and allows real-time corrosion monitoring. The distributed sensor data can be used to estimate the corrosion induced steel loss and predict concrete cracking.
KW - Corrosion monitoring
KW - Distributed fiber optic sensor
KW - Electrochemical test
KW - Expansion strain
KW - Installation
KW - Pull-out test
KW - Steel mass loss
UR - http://www.scopus.com/inward/record.url?scp=85056033839&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85056033839&partnerID=8YFLogxK
U2 - 10.3390/s18113722
DO - 10.3390/s18113722
M3 - Article
C2 - 30388844
AN - SCOPUS:85056033839
SN - 1424-8220
VL - 18
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 11
M1 - 3722
ER -