Flame diagnostic using optoacoustic laserbeam deflection and frequency modulation spectroscopy

W. Zapka, P. Pokrowsky, E. A. Whittaker, A. C. Tam, G. C. Bjorklund

Research output: Contribution to journalArticlepeer-review

Abstract

Two laser-based techniques, Optoacoustic Laserbeam Deflection (OLD) and Frequency Modu­lation (FM) spectroscopy, were introduced for flame diagnostics. Flame temperature was measured by OLD with 1.5% precision and flame temperature profiles were taken. Ground state and excited state sodium within an aspirated flame were detected by FM-spectroscopy. Present limits of sensitivity are absorptions of 1.5·10–4and ground state sodium densi­ties of 3.3·106 cm–3.

Original languageEnglish
Pages (from-to)302-308
Number of pages7
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume398
DOIs
StatePublished - 26 Oct 1983

Fingerprint

Dive into the research topics of 'Flame diagnostic using optoacoustic laserbeam deflection and frequency modulation spectroscopy'. Together they form a unique fingerprint.

Cite this