T1 - Hexavalent chromium removal mechanism using conducting polymers
AU - Krishnani, K. K.
AU - Srinives, Sira
AU - Mohapatra, B. C.
AU - Boddu, V. M.
AU - Hao, Jumin
AU - Meng, X.
AU - Mulchandani, Ashok
PY - 2013/5/5
Y1 - 2013/5/5
N2 - We report detoxification of Cr(VI) into Cr(III) using electrochemically synthesized polyaniline (PANI), polypyrrole (PPY), PANI nanowires (PANI-NW) and palladium-decorated PANI (PANI-Pd) thin films. Percent Cr(VI) reduction was found to be decreased with an increase in pH from 1.8 to 6.8 and with initial Cr(VI) concentration ranging from 2.5 to 10. mg/L. Efficacy of PANI increased at higher temp of 37 °C as compared to 30 °C. PANI-Pd was found to be most effective for all three initial Cr(VI) concentrations at pH 1.8. However, efficacy of PANI-Pd was significantly reduced at higher pHs of 5 and 6.8. Efficacy of PANI and PANI-NW was found to nearly the same. However, there was a significant reduction in effectiveness of PANI-NW at 10. mg/L of Cr(VI) at all the three pHs studied, which could be attributed to degradation of PANI-NW by higher initial Cr(VI) concentration. PPY and PANI-NW were found to be highly sensitive with respect to pH and Cr(VI) initial concentration. Chromium speciation on PANI film was carried out by total chromium analysis and XPS, which revealed Cr(III) formation and its subsequent adsorption on the polymer. PANI-Pd and PANI are recommended for future sensor applications for chromium detection at low pH.
AB - We report detoxification of Cr(VI) into Cr(III) using electrochemically synthesized polyaniline (PANI), polypyrrole (PPY), PANI nanowires (PANI-NW) and palladium-decorated PANI (PANI-Pd) thin films. Percent Cr(VI) reduction was found to be decreased with an increase in pH from 1.8 to 6.8 and with initial Cr(VI) concentration ranging from 2.5 to 10. mg/L. Efficacy of PANI increased at higher temp of 37 °C as compared to 30 °C. PANI-Pd was found to be most effective for all three initial Cr(VI) concentrations at pH 1.8. However, efficacy of PANI-Pd was significantly reduced at higher pHs of 5 and 6.8. Efficacy of PANI and PANI-NW was found to nearly the same. However, there was a significant reduction in effectiveness of PANI-NW at 10. mg/L of Cr(VI) at all the three pHs studied, which could be attributed to degradation of PANI-NW by higher initial Cr(VI) concentration. PPY and PANI-NW were found to be highly sensitive with respect to pH and Cr(VI) initial concentration. Chromium speciation on PANI film was carried out by total chromium analysis and XPS, which revealed Cr(III) formation and its subsequent adsorption on the polymer. PANI-Pd and PANI are recommended for future sensor applications for chromium detection at low pH.
KW - Chemical reduction
KW - Conducting polymers
KW - Cr(VI) remediation
KW - Mechanism
UR - http://www.scopus.com/inward/record.url?scp=84874966898&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84874966898&partnerID=8YFLogxK
U2 - 10.1016/j.jhazmat.2013.01.079
DO - 10.1016/j.jhazmat.2013.01.079
M3 - Article
C2 - 23507365
AN - SCOPUS:84874966898
SN - 0304-3894
VL - 252-253
SP - 99
EP - 106
JO - Journal of Hazardous Materials
JF - Journal of Hazardous Materials
ER -