Abstract
A multi-harmonic, frequency domain analysis of dry friction damped systems is presented which uses an incremental harmonic balance method. When compared with time domain solution methods, it is found that the incremental harmonic balance method can yield very accurate results with some advantages over the time domain methods. Both one and two degree-of-freedom systems are studied.
Original language | English |
---|---|
Journal | American Society of Mechanical Engineers (Paper) |
State | Published - 1985 |