Objective Determination of Eating Occasion Timing: Combining Self-Report, Wrist Motion, and Continuous Glucose Monitoring to Detect Eating Occasions in Adults With Prediabetes and Obesity

  • Collin J. Popp
  • , Chan Wang
  • , Adam Hoover
  • , Louis A. Gomez
  • , Margaret Curran
  • , David E. St-Jules
  • , Souptik Barua
  • , Mary Ann Sevick
  • , Samantha Kleinberg

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Background: Accurately identifying eating patterns, specifically the timing, frequency, and distribution of eating occasions (EOs), is important for assessing eating behaviors, especially for preventing and managing obesity and type 2 diabetes (T2D). However, existing methods to study EOs rely on self-report, which may be prone to misreporting and bias and has a high user burden. Therefore, objective methods are needed. Methods: We aim to compare EO timing using objective and subjective methods. Participants self-reported EO with a smartphone app (self-report [SR]), wore the ActiGraph GT9X on their dominant wrist, and wore a continuous glucose monitor (CGM, Abbott Libre Pro) for 10 days. EOs were detected from wrist motion (WM) using a motion-based classifier and from CGM using a simulation-based system. We described EO timing and explored how timing identified with WM and CGM compares with SR. Results: Participants (n = 39) were 59 ± 11 years old, mostly female (62%) and White (51%) with a body mass index (BMI) of 34.2 ± 4.7 kg/m2. All had prediabetes or moderately controlled T2D. The median time-of-day first EO (and interquartile range) for SR, WM, and CGM were 08:24 (07:00-09:59), 9:42 (07:46-12:26), and 06:55 (04:23-10:03), respectively. The median last EO for SR, WM, and CGM were 20:20 (16:50-21:42), 20:12 (18:30-21:41), and 21:43 (20:35-22:16), respectively. The overlap between SR and CGM was 55% to 80% of EO detected with tolerance periods of ±30, 60, and 120 minutes. The overlap between SR and WM was 52% to 65% EO detected with tolerance periods of ±30, 60, and 120 minutes. Conclusion: The continuous glucose monitor and WM detected overlapping but not identical meals and may provide complementary information to self-reported EO.

Original languageEnglish
Pages (from-to)266-272
Number of pages7
JournalJournal of Diabetes Science and Technology
Volume18
Issue number2
DOIs
StatePublished - Mar 2024

Keywords

  • chrononutrition
  • fasting
  • intermittent fasting
  • meal detection
  • meal timing
  • wearable sensors