TY - JOUR
T1 - Optimization and analysis of homogenous Fenton process for the treatment of dry-spun acrylic fiber manufacturing wastewater
AU - Wei, Jian
AU - Song, Yonghui
AU - Meng, Xiaoguang
AU - Pic, Jean Stéphane
N1 - Publisher Copyright:
© 2014 Balaban Desalination Publications. All rights reserved.
PY - 2015/12/11
Y1 - 2015/12/11
N2 - In this study, the homogenous Fenton process was employed for the pretreatment of dry-spun acrylic fiber (DAF) manufacturing wastewater. Central composite design and response surface methodology (RSM) were used for the design and optimization of the Fenton process. A second-order polynomial regression equation was developed to describe the chemical oxygen demand (COD) removal efficiency of Fenton process and validated by the analysis of variance and residual techniques. The interaction effects of the operational parameters were investigated using response surface analysis. The optimum parameters were determined as 90.00 mM H2O2, 30.00 mM Fe2+, pH of 3.14, and reaction time of 114 min. Under the optimum reaction conditions, the COD removal efficiency was 47.1%, which was highly consistent with the value predicted by the model equation, with a deviation of 2.89%. Furthermore, the biodegradability and toxicity of raw and treated wastewater were compared; the results showed that the (BOD5)/COD (B/C) ratio increased from 0.35 to 0.67, whereas the light loss of Vibrio fisheri bacteria decreased from 92 to 31%. The Fenton process was an effective method for pretreating DAF wastewater, and RSM was suitable for process design and optimization.
AB - In this study, the homogenous Fenton process was employed for the pretreatment of dry-spun acrylic fiber (DAF) manufacturing wastewater. Central composite design and response surface methodology (RSM) were used for the design and optimization of the Fenton process. A second-order polynomial regression equation was developed to describe the chemical oxygen demand (COD) removal efficiency of Fenton process and validated by the analysis of variance and residual techniques. The interaction effects of the operational parameters were investigated using response surface analysis. The optimum parameters were determined as 90.00 mM H2O2, 30.00 mM Fe2+, pH of 3.14, and reaction time of 114 min. Under the optimum reaction conditions, the COD removal efficiency was 47.1%, which was highly consistent with the value predicted by the model equation, with a deviation of 2.89%. Furthermore, the biodegradability and toxicity of raw and treated wastewater were compared; the results showed that the (BOD5)/COD (B/C) ratio increased from 0.35 to 0.67, whereas the light loss of Vibrio fisheri bacteria decreased from 92 to 31%. The Fenton process was an effective method for pretreating DAF wastewater, and RSM was suitable for process design and optimization.
KW - Central composite design
KW - Dry-spun acrylic fiber wastewater
KW - Fenton
KW - Optimization
KW - Response surface methodology
UR - http://www.scopus.com/inward/record.url?scp=84947028267&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84947028267&partnerID=8YFLogxK
U2 - 10.1080/19443994.2014.965223
DO - 10.1080/19443994.2014.965223
M3 - Article
AN - SCOPUS:84947028267
SN - 1944-3994
VL - 56
SP - 3036
EP - 3043
JO - Desalination and Water Treatment
JF - Desalination and Water Treatment
IS - 11
ER -