TY - JOUR
T1 - Polymeric nanofibrous nerve conduits coupled with laminin for peripheral nerve regeneration
AU - Chang, Wei
AU - Shah, Munish B.
AU - Zhou, Gan
AU - Walsh, Kevin
AU - Rudraiah, Swetha
AU - Kumbar, Sangamesh G.
AU - Yu, Xiaojun
N1 - Publisher Copyright:
© 2020 IOP Publishing Ltd.
PY - 2020
Y1 - 2020
N2 - Artificial nerve guidance conduits (NGCs) are being investigated as an alternative to autografts, since autografts are limited in supply. A polycaprolactone (PCL)-based spiral NGC with crosslinked laminin on aligned nanofibers was evaluated in vivo post a successful in vitro assessment. PC-12 cell assays confirmed that the aligned nanofibers functionalized with laminin were able to guide and enhance neurite outgrowth. In the rodent model, the data demonstrated that axons were able to regenerate across the critical nerve gap, when laminin was present. Without laminin, the spiral NGC with aligned nanofibers group resulted in a random cluster of extracellular matrix tissue following injuries. The reversed autograft group performed best, showing the most substantial improvement based on nerve histological assessment and gastrocnemius muscle measurement. Nevertheless, the recovery time was too short to obtain meaningful data for the motor functional assessments. A full motor recovery may take up to years. An interesting observation was noted in the crosslinked laminin group. Numerous new blood capillary-like structures were found around the regenerated nerve. Owing to recent studies, we hypothesized that new blood vessel formation could be one of the key factors to increase the successful rate of nerve regeneration in the current study. Overall, these findings indicated that the incorporation of laminin into polymeric nerve conduits is a promising strategy for enhancing peripheral nerve regeneration. However, the best combination of contact-guidance cues, haptotactic cues, and chemotactic cues have yet to be realized. The natural sequence of nerve regeneration should be studied more in-depth before modulating any strategies.
AB - Artificial nerve guidance conduits (NGCs) are being investigated as an alternative to autografts, since autografts are limited in supply. A polycaprolactone (PCL)-based spiral NGC with crosslinked laminin on aligned nanofibers was evaluated in vivo post a successful in vitro assessment. PC-12 cell assays confirmed that the aligned nanofibers functionalized with laminin were able to guide and enhance neurite outgrowth. In the rodent model, the data demonstrated that axons were able to regenerate across the critical nerve gap, when laminin was present. Without laminin, the spiral NGC with aligned nanofibers group resulted in a random cluster of extracellular matrix tissue following injuries. The reversed autograft group performed best, showing the most substantial improvement based on nerve histological assessment and gastrocnemius muscle measurement. Nevertheless, the recovery time was too short to obtain meaningful data for the motor functional assessments. A full motor recovery may take up to years. An interesting observation was noted in the crosslinked laminin group. Numerous new blood capillary-like structures were found around the regenerated nerve. Owing to recent studies, we hypothesized that new blood vessel formation could be one of the key factors to increase the successful rate of nerve regeneration in the current study. Overall, these findings indicated that the incorporation of laminin into polymeric nerve conduits is a promising strategy for enhancing peripheral nerve regeneration. However, the best combination of contact-guidance cues, haptotactic cues, and chemotactic cues have yet to be realized. The natural sequence of nerve regeneration should be studied more in-depth before modulating any strategies.
KW - aligned nanofiber
KW - biomaterial
KW - laminin
KW - nerve conduit
KW - peripheral nerve regeneration
KW - tissue engineering
UR - http://www.scopus.com/inward/record.url?scp=85081080781&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85081080781&partnerID=8YFLogxK
U2 - 10.1088/1748-605X/ab6994
DO - 10.1088/1748-605X/ab6994
M3 - Article
C2 - 31918424
AN - SCOPUS:85081080781
SN - 1748-6041
VL - 15
JO - Biomedical Materials (Bristol)
JF - Biomedical Materials (Bristol)
IS - 3
M1 - 035003
ER -