TY - JOUR
T1 - Quantification and remote detection of nitro explosives by helium plasma ionization mass spectrometry (HePI-MS) on a modified atmospheric pressure source designed for electrospray ionization
AU - Yang, Zhihua
AU - Pavlov, Julius
AU - Attygalle, Athula B.
PY - 2012/7
Y1 - 2012/7
N2 - Helium Plasma Ionization (HePI) generates gaseous negative ions upon exposure of vapors emanating from organic nitro compounds. A simple adaptation converts any electrospray ionization source to a HePI source by passing helium through the sample delivery metal capillary held at a negative potential. Compared with the demands of other He-requiring ambient pressure ionization sources, the consumption of helium by the HePI source is minimal (20-30 ml/min). Quantification experiments conducted by exposing solid deposits to a HePI source revealed that 1 ng of 2,4,6-trinitrotoluene (TNT) on a filter paper (about 0.01 ng/mm2) could be detected by this method. When vapor emanating from a 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) sample was subjected to helium plasma ionization mass spectrometry (HePI-MS), a peak was observed at m/z 268 for (RDX•NO2)-. This facile formation of NO2- adducts was noted without the need of any extra additives as dopants. Quantitative evaluations showed RDX detection by HePI-MS to be linear over at least three orders of magnitude. TNT samples placed even 5 m away from the source were detected when the sample headspace vapor was swept by a stream of argon or nitrogen and delivered to the helium plasma ion source via a metal tube. Among the tubing materials investigated, stainless steel showed the best performance for sample delivery. A system with a copper tube, and air as the carrier gas, for example, failed to deliver any detectable amount of TNT to the source. In fact, passing over hot copper appears to be a practical way of removing TNT or other nitroaromatics from ambient air.
AB - Helium Plasma Ionization (HePI) generates gaseous negative ions upon exposure of vapors emanating from organic nitro compounds. A simple adaptation converts any electrospray ionization source to a HePI source by passing helium through the sample delivery metal capillary held at a negative potential. Compared with the demands of other He-requiring ambient pressure ionization sources, the consumption of helium by the HePI source is minimal (20-30 ml/min). Quantification experiments conducted by exposing solid deposits to a HePI source revealed that 1 ng of 2,4,6-trinitrotoluene (TNT) on a filter paper (about 0.01 ng/mm2) could be detected by this method. When vapor emanating from a 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) sample was subjected to helium plasma ionization mass spectrometry (HePI-MS), a peak was observed at m/z 268 for (RDX•NO2)-. This facile formation of NO2- adducts was noted without the need of any extra additives as dopants. Quantitative evaluations showed RDX detection by HePI-MS to be linear over at least three orders of magnitude. TNT samples placed even 5 m away from the source were detected when the sample headspace vapor was swept by a stream of argon or nitrogen and delivered to the helium plasma ion source via a metal tube. Among the tubing materials investigated, stainless steel showed the best performance for sample delivery. A system with a copper tube, and air as the carrier gas, for example, failed to deliver any detectable amount of TNT to the source. In fact, passing over hot copper appears to be a practical way of removing TNT or other nitroaromatics from ambient air.
KW - API
KW - TNT
KW - electron capture
KW - explosives
KW - helium ionization
KW - negative ions
UR - http://www.scopus.com/inward/record.url?scp=84863954944&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84863954944&partnerID=8YFLogxK
U2 - 10.1002/jms.3026
DO - 10.1002/jms.3026
M3 - Article
AN - SCOPUS:84863954944
SN - 1076-5174
VL - 47
SP - 845
EP - 852
JO - Journal of Mass Spectrometry
JF - Journal of Mass Spectrometry
IS - 7
ER -