TY - JOUR
T1 - Robust identification of three-dimensional thumb and index finger kinematics with a minimal set of markers
AU - Nataraj, Raviraj
AU - Li, Zong Ming
PY - 2013
Y1 - 2013
N2 - This study presents a methodology to determine thumb and index finger kinematics while utilizing a minimal set of markers. The motion capture of skin-surface markers presents inherent challenges for the accurate and comprehensive measurement of digit kinematics. As such, it is desirable to utilize robust methods for assessing digit kinematics with fewer markers. The approach presented in this study involved coordinate system alignment, locating joint centers of rotation, and a solution model to estimate three-dimensional (3-D) digit kinematics. The solution model for each digit was based on assumptions of rigid-body interactions, specific degrees of freedom (DOFs) at each located joint, and the aligned coordinate system definitions. Techniques of inverse kinematics and optimization were applied to calculate the 3-D position and orientation of digit segments during pinching between the thumb and index finger. The 3-D joint center locations were reliably fitted with mean coefficients of variation below 5%. A parameterized form of the solution model yielded feasible solutions that met specified tolerance and convergence criteria for over 85% of the test points. The solution results were intuitive to the pinching function. The thumb was measured to be rotated about the CMC joint to bring it into opposition to the index finger and larger rotational excursions (>10 deg) were observed in flexion/extension compared to abduction/adduction and axial rotation for all joints. While the solution model produced results similar to those computed from a full marker set, the model facilitated the usage of fewer markers, which inherently lessened the effects of passive motion error and reduced the post-experimental effort required for marker processing.
AB - This study presents a methodology to determine thumb and index finger kinematics while utilizing a minimal set of markers. The motion capture of skin-surface markers presents inherent challenges for the accurate and comprehensive measurement of digit kinematics. As such, it is desirable to utilize robust methods for assessing digit kinematics with fewer markers. The approach presented in this study involved coordinate system alignment, locating joint centers of rotation, and a solution model to estimate three-dimensional (3-D) digit kinematics. The solution model for each digit was based on assumptions of rigid-body interactions, specific degrees of freedom (DOFs) at each located joint, and the aligned coordinate system definitions. Techniques of inverse kinematics and optimization were applied to calculate the 3-D position and orientation of digit segments during pinching between the thumb and index finger. The 3-D joint center locations were reliably fitted with mean coefficients of variation below 5%. A parameterized form of the solution model yielded feasible solutions that met specified tolerance and convergence criteria for over 85% of the test points. The solution results were intuitive to the pinching function. The thumb was measured to be rotated about the CMC joint to bring it into opposition to the index finger and larger rotational excursions (>10 deg) were observed in flexion/extension compared to abduction/adduction and axial rotation for all joints. While the solution model produced results similar to those computed from a full marker set, the model facilitated the usage of fewer markers, which inherently lessened the effects of passive motion error and reduced the post-experimental effort required for marker processing.
KW - Digits
KW - Hand
KW - Kinematics
KW - Motion analysis
KW - Optimization
KW - Precision pinch
UR - http://www.scopus.com/inward/record.url?scp=84880858913&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84880858913&partnerID=8YFLogxK
U2 - 10.1115/1.4024753
DO - 10.1115/1.4024753
M3 - Article
C2 - 23775305
AN - SCOPUS:84880858913
SN - 0148-0731
VL - 135
JO - Journal of Biomechanical Engineering
JF - Journal of Biomechanical Engineering
IS - 9
M1 - 091002
ER -